格力空故障代码e1(格力空调故障代码e6)

作者:admin 浏览量:91 时间:2022-07-22 03:50:10

今天给各位分享格力空故障代码e1的知识,其中也会对格力空调故障代码e6进行解释,如果能碰巧解决你现在面临的问题,别忘了关注本站,现在开始吧!

本文目录一览:

格力空调代码故障原因E1是什么原因

格力空调故障代码\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aKF-60L WAK分体立柜式房间空调器故障代码:\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE1 1、冷凝器前有障碍物\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a2、控制回路巽常\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3、室外环境温度高于43度时开始制冷\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a4、高压管压力过大使高压开关动作\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE2 1、室内风机不转或风口堵住\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a2、室内环境温度低于18度\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3、管温感温头折断\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a4、管温感温头插头没插好\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a5、控制回路巽常\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a6、电容C7漏电\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aLF-12WAK分体立柜式房间空调器故障代码:\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE1 1、冷凝器前有障碍物\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a2、控制回路巽常\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3、三相电源缺相\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3、室外环境温度高于43度时开始制冷\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a4、工作电流过大使过护器动作或高压管压力过大使高压开关动作\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE2 1、室内风机不转或风口堵住\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a2、室内环境温度低于18度\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3、管温感温头折断\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a4、管温感温头插头没插好\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a5、控制回路巽常\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a6、电容C7漏电\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a格力:变频柜机E1-E5\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE1:压机过流,过热,排气过高,模块保护;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE2:室内防冻结保护;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE3:室内温度感温包开,短路;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE4:室内管温开,短路;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE5:室内外通讯故障。\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a:定频机故障代码:\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE1:压缩机高压保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE2:蒸发器防冻结保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE3:压缩机低压保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE4:压缩机排气温度过高保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE5:过电流(低电压保护)\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a格力空调维修数据\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a一:格力定频机器挂机的传感器的阻值比较小,也就是说比较精确,不过也是最容易坏的!常见故障就不说了!说2个不好查的:1制冷时20分钟左右压机停;2制热外风机不工作;很大可能都是室内管温问题![适用所有定频机]\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a二:普通分体机,1:就是带灯箱的E1表现为一开机立刻停,除灯箱可以开以外别的功能都没有用。[简单解决 *** :将控制板的OVC线与零线短接,仍是E1为控制板坏,不显示E1那就是高压保护开关等断开]2:E3故障有的机器根本就没有低压保护开关,可是换了所有控制元件还是解决不了问题,原来是现在的很多控制板都是通用的,只要把控制板上的LPP线与零线短接就可以了!\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a三:变频冷静王维修资料\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a1 排气温度保护:当T排气高于115度时,压机停,小于90度压机停已达三分钟后恢复运行;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a2 防冻结保护:当T内管小于-1度,压机停,大于6度压机停已达三分钟恢复运行;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3 过电流保护:当I总大于D时,压机停,外风机30秒停\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a制冷时32机D=10A,25机D=8A;制热时32机D=13A,25机D=10A\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a4 过负荷保护:当T管大于62度时,内风机按设定风速运行,压机停。\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aT管:制冷时是室外热交换器温度,制热时是室内热交换器温度。\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a5 室内,外故障显示:D1,D2,D3为内机灯,LED1[绿灯]LED2[红灯]LED3[黄灯]为外机灯。\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aA压机停且有故障时LED1亮;B室外环境温度有故障时LED3亮;C室外管温有故障时LED2亮;D模块保护时LED1闪烁;E压机过载时LED2与LED3同时闪烁;F排气温度有故障时LED1,LED2,LED3全亮;G室内D1压机运行时亮;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aH室内D2时通讯指示,正常时闪烁;I室内D3是感温包指示灯,有故障时闪烁。\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a6 功率模快:各线功能\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a1号线:W相的负端控制信号;2号线:W的正端控制信号;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a3号线:V的负端控制信号;4号线:V正端控制信号;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a5号线:U的负端控制信号;6号线:U正端控制信号;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a7号线:地线;8号线;+5V线;9号线:+12V线;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a10号线:模块保护信号线[模块保护有:过热,过流,欠压保护,保护时模块有微秒极的信号输出]\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0a四:变频柜机E1-E5\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE1:压机过流,过热,排气过高,模块保护;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE2:室内防冻结保护;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE3:室内温度感温包开,短路;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE4:室内管温开,短路;\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE5:室内外通讯故障。五:定频机故障代码:\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE1:压缩机高压保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE2:蒸发器防冻结保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE3:压缩机低压保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE4:压缩机排气温度过高保护\\\\\\\\\\\\\\\\x0d\\\\\\\\\\\\\\\\x0aE5:过电流(低电压保护)

格力空调e1是什么故障,如何处理

格力空调显示E1是压缩机高压保护。

压缩机电流过大,压缩机过热、排气温度高、模块保护,应检查过载保护器有无断开及压缩机感温包是否短路。

解决 *** :

1、先用喷枪将室外机冲洗干净看是否是因为室外机散热不良导致的问题。

2、然后检查室外风机,如果不转的话,我们大家只需要更换风机和风扇电容器就行。

3、最后再检查一下是否是高压保护导致的,如果是,需要对高压保护器以及信号线和控制面板等方面进行维修。

相关信息:

一般出现这个问题的可能性有:线路问题,主板问题,保护器本身问题。需要做的就是要查看线路,内外机连接线有没有断,以及是否有接地线,还有就是查看是否加过管线,加过铜管,加管的同时也要加线,然后看电源线与信号线是否接好,若是没有问题的话就排出线路问题。

然后是检查是否是主板问题,是否是主机漏电,需要先查线路再查压缩机,如是压缩机只能换一个了。除此之外还有涉及到室外机是否散热,外机散热是否理想,是否是内外机过滤网过脏导致,也就是冷凝器脏了。

若是排出了过滤网与冷凝器之外还要看看是否是制冷剂的缘故导致,也就是要检查氟是否过多或者过少,若都不是,那么就是保护器本身的问题了。有可能是电流瞬间过大,导致过护器动作或高压管压力过大,而产生的高压保护。

格力柜机空调显示E1是什么故障?

格力空调显示E1的意思是:压缩机高压保护。

显示E1的原因可能是:压缩机鼓藏,压缩机卡缸或冷冻油不足,解决 *** :更换冷冻油或直接更换空调压缩机。

散热翅片脏堵、室外散热不良造成的高压排气温度过高而保护。解决 *** 用专用的翅片清洗剂清洗翅片。当压缩机排气温度开关损坏、开路状态时也可能出现“E1”故障,更换或短接线路即可解决。

使用注意:

室外机组安装要牢靠,减少振动和噪音,冷凝器的吸、排风口前要留有足够空间以利通风,若风力受阻,冷凝压力升高将会导致停机;

室内机组前也不应有障碍物,否则影响出风;空调器刚运转时为急速降温可将选择开关调至高速档,待温度下降后再调至中速低速档;

窗式空调器通风换气可使用通风开关,但换气时间不超过15分钟。

格力中央空调故障码E1什么原因,怎么修吧?

需要清洗室外机。

室内、外换热器表面清洗,提高换热器的效率。清理室内换热器时,应小心拿下面板,用柔软的抹布擦洗,使用小毛刷轻轻刷洗完内机的换热器,这样达到清除灰尘和可繁殖病菌的有害积聚物的目的。

清洗过滤网上的积灰,在清洗过滤网的时候,首先切断电源,再打开进风栅;取出过滤网,用水或吸尘器清洗过滤网,水温不要超过40度,用热的湿布或中性洗涤剂清洗,然后用干布擦净,同时不能用杀虫剂或其他化学洗涤剂清洗过滤网。

格力空调显示e1空调故障代码也可能是室内机和室外机通讯故障。

(1)首先确定空调是运行了一段时间出现故障还是开机就出现了故障,用来区分是系统故障还是电路故障。

(2)空调显示e1故障代码说明压缩机电流过大,压缩机过热、排气温度高、模块保护,应检查过载保护器有没有断开及压缩机感温包是否短路。

格力5匹空调出现e1是什么故障?

1、格力空调显示空调故障代码e1可能是室内机和室外机通讯故障;

2、如果出现了空调故障代码e1说明压缩机电流过大,压缩机过热、排气温度高、模块保护,应检查过载保护器有无断开及压缩机感温包是否短路;

3、您可以打开室内机壳观察室内机电路板上的绿色指示灯是否闪亮,若闪亮则外板坏,不闪则内机板坏。这是因为室内机只有接收到外机发出的脉冲信号时绿灯才亮同时向室内机发出信号,室内外机进行通讯;

4、还有可能是由于冷凝器前有障碍物、室外环境温度高于43度时开始制冷、控制回路异常、高压管压力过大使高压开关堵住。

关于格力空故障代码e1和格力空调故障代码e6的介绍到此就结束了,不知道你从中找到你需要的信息了吗 ?如果你还想了解更多这方面的信息,记得收藏关注本站。